Loading...
HomeMy WebLinkAbout25-2S Rondeau1/8/25, 8:41 AM BAYFIELD COUNTS Carmody™ SANITARY PERMIT (#04)-25^S STATE SANITARY PERMIT OWNER: NATHAN J RONDEAU GOV'TLOT: LOT: 1 BLK: NE 1/4 SE 1/4 SEC: 14, T 43 N, R 8 W TOWNSHIP: Cable SOIL TEST: 24-10 OTHER MODIFICATION SYSTEM jyPE: Other (NEW TANK) PLUMBER: Edward B Redinger CECE RUDNICKI Authorized Issuing Officer DATE: 1/7/2025 CHAPTER 145.135(2) WISCONSIN STATUTES a. The purpose of the sanitary permit is to allow installation of the private sewage system described in the permit. b. The approval of the sanitary permit is based on regulations in force on the date of approval. c. The sanitary permit is valid and may be renewed for specified period. d. Changed regulations will not impair the validity of a sanitary permit. e. Renewal of the sanitary permit will be based on regulations in force at the time renewal is sought, and that changed regulations may impede renewal. f. The sanitary permit is transferable. History: 1977 C. 168; 1979 c. 34,221; 1981 C. 314 Note: If you wish to renew the permit, or transfer ownership of the permit, please contact the county authority. PREVIOUS PERMIT #: 10-17S LICENSE: #221939 Condition: System to meet all setbacks. Management Plan to Owner(s). Properly maintain system per recorded agreement. Adhere to State approval/conditions. THIS PERMIT EXPIRES 1/7/2027 POST IN PLAIN VIEW MUST BE VISIBLE From ROAD FRONTING THE LOT DURING CONSTRUCTION https://www.carmodyinc.com/PermitApp/Permit_Sign.aspx?Print=1&permitappid=7431 1/2 SS-OD.Csnn Iinhistty Services Division -48:;M;ttlisouYai<i!;W.iy Madison. WI 537U5 P.O. Box 73(U Miitli.wn, WI 53707 Sanitary Permit Application ti ! ' hnifronliuice with Sl*S.<i<.<.21<21.Wis.Adin.<;'<Hlc. submission of diii. lunn to llie appropnali; govenunenlal liiui is rcijiiired prioi to obi.iinins >i !i<uiiiaiy permit. Noie: Applicaiinu fnnns t'or slate-owntd PO\\TS are subinined lo ihe Dcp.irtiBMt of Sal'ff,' nnd Professional Sen'ici'i; Prrsoaal iufoitiwliint you provide tuay be used {m secondary puqwscs in accordance with tbc Pwacy Law. s. 15.(M(JKHi), Suis. I. Application Information - Please Print Alt Infonnation OnunyBayfield Saniiaiy Pmiul Nunibei Hi) lie iillsd in bv Cu I it ?°BS&il " ^•^>•<:ll ffi^e Trans.ictionNurnlier n-ftjecl Address (ifdiffert'iu tli.in in.iitinp nddress)Same Prapcny Owner's >.'auie Nathan Rondeau P.UC<1=9447 I'lfpeny Owner'i. M-iilins Address43450 Big Brook Rd. t'HV. StaleCable, Wl Zip Code54821 IT. Type ofBuildine (check all that apply) •ll ui 2 Faimly Dwdlina - Niunbef ofBniraflins 2. HUtc/Conunw-ial - Dea'ribeUse, 1-Sl.ite Owued - Peicnbc l'te Phone Number303-906-4877 Lot = I'nipctiy Lofatkin Ciovt.Lol NE__.,SE_.,^<K,ul4 T.i3_N R 8_E or W.Snbdivisiou NDUK Biofk a Ijciiyn;L'l< CSM dumber Qv'lll.lgiof • ITnn-n of Cable III. Type of POWTS Permit: (Check either "New" or "Ileplncemrat" sinit other applicable on line A. Check one box on line B. Complete line C if| applicable.)&ew Svsteiu tepllacemelM Syi.tem lilier Mdtificadou ICT Existinp Syycm mplain)lAddilipnal rreirealnitftil t'nit fexplnuii B.[|Holdine T-uik IIn-Cronuti lconveiinoua!) I[^i-Cinnlc n.Moundp^ ? Individual Site Design r|0llier Type lcxpliiuiiTew Tank <.D Renewal Bcioitf Expiration [Revision 'hanse of Plumber riuisi'ei to New Owninlisl Previous Permil Nuiulwr and Date IssuedI10-17S-4/29/10 W. DKpersaLTrentmentArea and Tank Information: Desi?uFlow(gptl>300 Design Soil Application Rfllcli.'pct'sftNA Dispersal Arcn Riquued (sllNA Disperial Area Proposed (sflNA Svslcin Elev;itioaNA T.ink lufonnatinit Capiicity lit ti.lllous N'ov T.iul;»Eiiivtiue TAnfct Total Cialions = of L'ntls Mamiiacniicr ^ ii 2.S 1—r li^ ^ ^c'ptK or Hol<lutp T.ii^~w ^Wieser Concrete aI>^ut^ Cii;itia1w V. Re'.poasibiliiv Statement- I, tlie undmtgnpd. atsuiue mptturibility ror Install.iliun or th? POnTSshomi on Hip atlnclifil plant, Plinnlw'sNamed'nKtl Edward B. Redinger Pltunber's SiptWHlK '• MP/MPRSNumbft221939 Busiucs. PIiom: Numb<:( 715-292-6670 PliUtiher's AAlKss (Street. Ciiy. Slate. Zip Cuile)1015 11th Ave. E. Ashland, VVI 54806 V:IceBttB%a)enartmentl!wOn]?- \V^"*S?A<-' x ^^. —," I Permn'V^i;Appiovcd ) Q Dir.iijiptoved O Owner Oiveu Rca'.on lor Hunial Permil Tie S_/; /,,•,;.'.::'40C'^' IWe IssilitlJ/5/Z4 {ssnuis Awst-Siiawiinre(lit.Stawmire i^^-A^_- ('tiinliti(in\ofApprov.il/Reasons for Disapproval StL Cdx-c^ Altiich I» cuuiplrtr ]ilaB< ht Ihf mtt-ui ami tuliiull 1« lb» Cuuniy ualy nn |upw nal IMI ihan 8 1/2 s 11 Inch" la Ar SBD.6?9S(R.U:/'22> Site Address m^o 6^6rooK^l Owner(s) Namerd alt A \<dt-6LO Bcnni-fc J-Wvu^ ,P.<S,A, Parcel Identifier Number (PIN)0^-01 Z - 2-4 S-£>0- H- 01- Ofic - 0^.000 Private Sewage System Maintenance Agreement Owner(s) Mailing Address43l(5"0 615 Bf&ok fS^., Cab ^ ^x ?^s-^' Agreement Date (same as Notary Date) ^l^-rj 10 As owner, I (we) do hereby certify the private sewage system will be installed in accordance with the certified soil tester's report and approved plans and specifications on file with Bayfield County Planning and Zoning Department. The system will be operated in such a manner as to meet the designed plans. I (we) agree to maintain said private system at the below listed location in accordance with rules established in the Wl Adm. Code. as from time to time amended. H6- 1/4 of c»£ 1/4 Section t ^ Township ^3 N. Range S W. Town of (_d!oie- ___ Gpv'tLot CSMffl/.-S P. .25-3Subdivision Additional Legal Description: U3«-</ R ^i^ Stily^cf- -fo 6A$<2m>u'\i- 77^ FATKJCJA A OLSOMBAfFIELD COUHTV, WIREGISTER OF OEEt).:. S0 1 IZIR—5;5^-^.3'=> 84/38/2®!® H-.iaAK TF Hi?1 *: RECORDING FEE: 15. M. Mis: ^ Return To: Sx^el^ Cc . 2cn.u^ (jOa.&kbu.-n ^r , J ^yll 3ZU^ Type of Private Sewage System: (A) In-ground gravity Q (B) In-ground dosed D (D) Mound D (E) At-grade Sewage System D (C) In-ground pressure distribution D Other Septic tank (System types A through E): The septic tank shall be pumped by a certified septage servicing operator within three (3) years of the date of installation and at least once every three (3) years thereafter unless, upon inspection by a licensed master plumber or other person authorized to make such inspection, the tank is found to have less than one-third (1/3) of the volume occupied by sludge and scum. Pump chamber (System types B, C. D, and E): The pump chamber shall also be rinsed and pumped out when the septic tank is serviced as provided above. The switches and pump controls shall also be inspected and maintained to ensure operability of said components. Septic tank effluent filter (System types A through E): The septic tank effluent filter shall be inspected and maintained as necessary and in accordance with manufacturer's specifications. Filter maintenance reports shall be submitted to the County as required by Comm 83 55, Wis. Admin. Code. Private sewage system dispersal cell (System types A through E): The private sewage system distribution cell shall be visually inspected by a certified septage sen/icing operator, POWTS inspector, or licensed master plumber within three (3) years of the date of installation and at least once every three (3) years thereafter to determine whether wastewater or effluent from the system is ponding on the ground surface. Mounds. At-grade. and tn-qround pressure system laterals (System types C, D and E): needed when the wastewater distribution cell component is inspected as provided above- The laterals shall be flushed out and swabbed if Owner(s) agree that failure to comply with this agreement wil! result in action being taken to pay all charges and costs incurred by Bayfield County for inspection, pumping, hauling, or otherwise servicing and maintaining the private sewage system tank in such a manner as to prevent or abate any human health hazard caused by the system. BayHeld County shall notify the owner of any costs which shall be paid by the owner within thirty (30) days from the date of notice. In the event the owner does not pay (he costs within thirty (30) days, the owner specifically agrees that all the costs and charges may be placed on the tax roll as a special assessment for the abatement of a human health hazard, and the tax shall be collected as provided by law. The terms and conditions of the variance shall be binding upon and inure to the benefit of all current and future owners of such property. Owner(s) Name(s) - Pleiase Print-^ de it a M, ^ vo ^ ^ ^ ^B'cmne z. ^ir^y ^^'^-' ^•ti^/1-k'i- for J^eitcL /Y\. favour Subscribed and sworn to before me on this date: ^y-^?7-/^ Notarized Owner(s) - Signature(s)Notary-public A?^^c ^. ^/iX-U^ ^0.^. dciU^^t^i^.\>i-^ CUcjj~ti ^ ^^t ^//. %-<^^.u My Commission-&<pires: C3-/^-f^ Drafted by: J^ <3cLSmuJ^ U/Deb'sData/Fonns/Sanitary/SeplicMaintenanceAgreement V1039 P 40 2008 4" CAST-A-SEAL ^ W"X6"-^ FLOW ^ >\^ THRU l-l 4" CAST-A-SEAL FILTER ORBAFFLE TOP VIEW SIDE VIEW TANKS ARE MANUFACTURED TO MEET OR EXCEED ASTM C-1227 REQUIREMENTS WLP700/500-MR TANK SPECIFICATIONS DIMENSIONS: WALL: 2 1/2"BOTTOM: 3" COVER: 5" MANHOLE: 24" I.D. PRECAST CONCRETE RISER HEIGHT: 53 1/4" LENGTH: 8'-8" WIDTH: 7'-2" BELOW INLET: 42"LIQUID LEVEL: 36WEIGHT: BOTTOM 3,595 LBS.COVER 3,195 LBS. INLET AND OUTLET:4" CAST-A-SEAL BOOT OR EQUAL GASKET INLET AND OUTLET BAFFLE AND FILTER:WISCONSIN, SEE DETAIL ^0(OTHER STATES SEE CHART) LIQUID CAPACITC: 26.79 GAL/IN LOADING DESIGN: 8'-0" UNSATURATED SOIL TANK CAN BE USED AS:SEPTIC / HOLDING COVER: MIX DESIGN #8 (NO FIBER)TANK: MIX DESIGN )j(10 (STRUCTURAL FIBER) CUSTOMIZED TANKS:FOR CUSTOM TANKS CONTACT WIESER CONCRETE REVIEWED BY REVIEW DATE DRAWINGS SUBMITTED FOR APPROVAL APPROVED BY: APPROVAL DATE: PRODUCTS NEEDED BY: X' 101^i°te int ^3^0 00i oo Q;2 Q0rr> 00sa, <=1 u CLS(7) SHEET NO. 1 OF n01 H3J" ^——p—y/' un'f/ .^CAST-A-^AL;;"X' /^^.i?) C3^—^ N^- FILTER _OR J mi^; "BAFFLE*^""""" ill! :^__UL; 11SS?^^^i iSo..,-s-'/// .^,^•^ W840/500-MR TANK SPECIFICATIONS 4" CAST-A-5EAL TOP VIEW 4" VENT OUTLET DIMENSIONS:WALL: 2 1/2" BOTTOM: 3" COVER: 5"MANHOLE; 24"'. I.D. PRECAST CONCRETE RISERHEIGHT: 59 1/2" 0.0. LENGTH: 113 3/48" O.D. WIDTH: 93° 0.0. BELOW INLET: 48" O.D.LIQUID LEVEL: 43" WIGHT: 11,150 LBS. INLET AND OUTLET:4° CAST-A-SEAL BOOT OR EQUALGASKET, CAST-A-SEAL BOOT OR EQUAL INLET AND OUTLET BAFFLE AND FILTER:WISCONSIN, SEE DETAIL fW(OTHER STATES SEE CHART) LIQUID CAPACITY: 19.61 GAL/IN (SEPTIC)11.82 GAL/IN (PUMP) LOADING DESIGN: 8' 0" UNSATURATED SOIL TANK CAN BE USED AS: SEPTIC/SEPTIC, SEPT1C/PUMP OR SEPTIC/SIPHON COVER; MIX DESiGN 46 (NO FIBER)TANK: MIX DESIGN §W (STRUCTURAL FIBER) CUSTOMIZED TANKS:FOR CUSTOM TANKS CONTACT WESER CONCRETE PUMP PAD SIDE VIEW TANKS ARE MANUFACTURED TO MEET OR EXCEED ASTM C-1227 REQUIREMENTS DRAWINGS SUBMITTEDFOR APPROVAL APPROVED BY; APPROVAL DATE; PRODUCTS NEEDED BY: >y: wg ca K tQ8m]w. ^z COlug Is mCMnI001 co <=} <2 0{=CLUJ(/) SHEET NO. 1.0./ PAGE 4 OF 4 In-ground Gravity Management Plan IMPORTANT: The owner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant to requirements of SPS 382-384, Wise. Admin. Code. Pursuant to SPS 383.52 (2), Wise. Admin. Code, this system shall be considered a human health hazard if not maintained in accordance with this approved management plan. Furthermore, all inspection and maintenance activities shall be performed by a registered POWTS Maintainer in accordance with SPS 383.52 (3), Wise. Admin. Code. Maximum Dispersal Area Operating Limits: Design Flow = 30° gpd; BODs ^ 220 mgL-1; TSS S 150 mgL-1; FOG $ 30 mgL-1 Inspection Checklist INSPECT EVERY 3 YEARS o type of use o age of system o nuisance factors (/'.e. odors, user complaints, etc.) o mechanical malfunction (/.e., pumps, valves, switches, floats, etc.) o material fatigue (/.e., leaks, breaks, corrosion, etc.} o solids volume in anaerobic treatment tank(s) and any distribution appurtenance(s) (i.e., distribution / drop boxes) o neglect or improper use (/.e., exceeding design capacities, prohibited activities, etc.} o extent of ponding in distribution cell prior to dosing o dosing irregularities - if applicable (/'.e., pump re-cycling, float switch settings, etc.) o electrical components - if applicable (/.e., wiring, connections, switches, controls, timers, alarms, etc.) o distribution laterat or lateral orifice plugging (measure lateral distal pressure - compare to design specification) o surface discharge of affluent or sewage back-up into structure served Maintenance Checklist MAINTAIN EVERY 3 YEARS (or when necessary) o Septic and dose tank(s) shall be pumped by a certified septage servicing operator licensed under s. 281.48 Wis. Stats, when the volume of solids in the tank(s) exceeds one-third (1/3) the liquid volume of the tank(s) or as required by local ordinance. Disposal of contents shall be pursuant to NR 113, Wise. Admin. Code. o Effluent filter(s) shall be inspected every 3 years and shall be cleaned when necessary to remove any accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 months. System maintenance reports shall be submitted to the proper local government unit in accordance with SPS 383.55 Wise. Admin. Code. Report any component failure or malfunction to: Name of individual or company: Superior Plumbing & Mech. Inc. phone: 715-292-6670 Local government unit: Bayfield CQ. Zoning _ phone: 715-373-6138 Local government unit address: 117 5th St. E. Washbum, Wl _ ZIP: 54891 Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1), Wise. Admin. Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383, Wise. Admin. Code. No product for chemical or physical restoration of the POWTS may be used unless approved by the department in accordance with SPS 384, Wise. Admin. Code. Contingency Plan In the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils. System Abandonment If use of this POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33, Wise. Admin. Code. PAGE 1 OF 4 In-Ground Gravity Plan Index & Cover Sheet Component Manual Design References: In-Ground Soil Absorption for POWTS Version 2.1 (May 2022-2027) Pg 1 of 4 Index & Cover Sheet Pg2of4 Plot Plan Pg 3 of 4 Dispersal Area Cross-Section & Plan View Pg 4 of 4 Management Plan Attachments:Enclosures: POWTS Application for Review Soil Evaluation Report & Site Map Project Name / Description New Septic/pump tank connected to existing drain field Owner Name(s): Nathan Rondeau _ Phone: 303 -906 -4877 Owner Address: 43450 Big Brook Rd. Cable, Wl _ Zip: 54821 Project Address: same Govt.Lot:m NE Ql/4ofsE Q 1/4, Section14 , T43 N-pS E or W • Township: Cable _ County: Bayfield Project Parcel ID #: 9447 Designer Information Designer Name: Edward B. Redinger _ Phone: 715 .292 _6670 Designer Address: 1015 HthAve.E. Ashland, Wl _ Zip: 54806 E-mail: ed@SUperiOrpmW.COm This space reserved for approval stamp. License Number: 221939 Remarks: Existing home was removed - New home will have new tank Signature: ^^-^^TZ^^^_ _ Date: 12/13/24 Original signature required on each submjtfed copy. SUPERIOR PLUMBING MECHANICAL (715)278-3456 Customer Name: Nathan Rondeau Adress: 4345° BiR Brool< Rd- Cable, Wl 54821 Phone #: 303-906-4877 Email: 1 ,\1 '33 CSTff 221939 Scale: 1" = 40' PIN:9447 ^Acres Lot 1&3 NE SE S14 T43N R8W V.2 P.253 Town of Cable Bayfield Co. ^ ^'^^^'^ ^i^"}^l( « —^^s1 ^,&(^ ^"^L^ C-.c^ mCL^~ 'J-.n<^(<?tV-<t /,<q<(. AJe*^' S^a-soo V^ /^ck^T€(^ ^^ -^ ^'y",^p' r^* t^^v"^ ^•^1^^ /j<^ 4 %^ ri^^-vt^ 6(^ (Sroo^ /3..I 2$o' r&Tflt. 3 (3- 04= o rT»N $ N i {fwI000 r—y — ,-_.LJ_-1-•<' —'-.— f^?£^f ^ '-. ~c ^~^ ^ p^ i?% s e- v-f ^ r^-^ s'.^fe&?^^ ^ 5T<< INFILTRATOR CHAMBER CROSS-SECTION r^' 3034, 3=H. 40 U " ^ 40 VewT/xuspe^ootj pi p£ s ^ CELL(S) ^L 3' X S^'{t'!f CELLS WITH /3 QUICK 4 CHAMBERS t ^ END Cf.P5 TOTAL SQ. FT.= 5" ^/' (r ,?^. CHAMBERS AT 20 5Q. FT. = $~2-0 SQ. FT. 'A SETS OF END CAPS @ 5 .8 = //. ^ SQ. FT; 4" SCH 40 PVC PIPE- .4" APPROVED VENT CAP OR INSPECTION CAP/ PLUG FINAL GRADE /C/. ^ ' ^ Schematicof SingIe-Layer System USING IKFILTRATOR QUICK 4 STANDARD CHAMBERS H.20 nrtltwcr C^.u-:f<l SYSTEM ELEV. <? 7. 5- ••PAGE—U~-£1•Ut 0 PAGE 4 OF 5 GRAVITY-DOSED SEPTIC / PUMP TANK SPECIFICATIONS(No Scale)4"0 Vent Pipe >10ft from Building 12" Win. or 2.0 It aboveEstablished Flood Elevation(typical)Approv&dVanl Cap Anchor tankfs) as necessary pursuant to SPS 383.43(8)(g) IMPORTANT: \1/ \k Finished Grade Extend manhoto riser as necsssary. Electrical musl comply mlhSRS 316 and NEC 300 Weathetpraof-Junction Box Approved LotAhg Manhotewith Warning Label Attached(typical) 4" Mtn. m 2.0 ft aboveEstablished Ftood Etevaljon(lyrical) -^k- CAPACITIES @ 11.82 gai/in Djmension A B c D Total Inches .24 3 6 10 43 Gallons 283.68 35.46 70.92 118.2 50S.26 Pump Tank Liquid Level = Force Main Diameter = 2 43 Approved Joints wffii Approved Pipe 3 ft ontoSolid Ground [typical} PUMPOFFELEVATION = Force Main Length =90 ft 3" Approved Bedding Malen'al Bensam Tank Force Main Void Volume = 14.6 ga| [C] Total Dose Volume (TDV) = (S0.2X design fl( 70.9 gal/dose :, 0.2X design flow + force main void voiume) Vertical Lift =6 ft PUMP TANK: Volume = 500 gal Manufacturer: Wieser Concrete Pump Manufacturer: _Gqylds Mode!: EPOAlwJ^20y (See altsched pump curve.) Controls/Alarm Manufacturer: SJE Rhombus Controls/AIarm Model: Power Post Float switches containing mercuryareBrobjbited. SgPTICTANK(S): Total Volume = 840 gal Manufacturers): _WieswConcrete, Install approved effluentfflterat^ immediately upstream of the pump tank inlet. Rlter Manufacturer: Orenco Filter Model: 8" Biotube / Existing Wastewater -!GioyNs:-V^'teilfe^ METERS, FEET 10 QI y I 10 10 GPM 6 . 8 CAPACITY 10 12 m3/h MODEL INFORMATION Order Number EP041} EP0411A EP0411F EP04HAC EPQ412 EP0412F EP0511F EP0511AC EP0512F HP .4 .5 Vote 115 230 115 230 Amps 12 6 13 6.5 Minimum Circuit Breaker 20 10 20 10 Phase 1 Float SwitchStyle Plug/No Switch Piggyback / Wide-Angt® Plug/ No Switch Piggyback / Wide-Angte Plug/No Switch Plug/ No Switch Plug/No Switch Piggyback /Wide-Angte Plug/No Switch Cord length 10' 10' 20' 20' 10- 20' 20' 20' 20' Discharge Connection w Minimum On Level Manual 12" Manual 12- Manual Manual Manual 12" Manual Minimum Off Level Manual 6" Manual 6- Manual Manual Manual 6" Manual Minimum Basin Diameter 15" Maximum Solids Size %" ShippingWeight Ibt.kg 20/9.1 21/9.5 20/9.1 21/9.5 20/9.1 20/9.1 22/10 23 /10.4 22/10 PAGE 3