HomeMy WebLinkAbout25-0246Return to:
117 E 51^ Street, PO Box 58
Washburn, WI 54891
perniits@bavfieldcounty.wi.gov
County Use Only:
Bayfield County Planning an ` oin��i�pJrt�teLtt lii \ Submission #: t -U- 0I XO
LAND USE PERMIT p I A ION Permit #: 2
APR 0 8 2025 !` Date: 5
SECTION A: General Information --
Property Owner Name:
Authorized Agent Name (if applicable):
Michael & Wendy Wethington
Karl Kastrosky
Telephone Number:
Telephone Number:
612-860-4123/715-798-2299
715-580-0157
E -Mail Address:
E -Mail Address:
mike@wethington.net
kastrosky821@gmail.com
Mailing Address:
Mailing Address:
1823 Irving Ave S
14295 McNaught Rd
City, State, Zip:
City, State, Zip:
Minneapolis, MN 55403
Cable, WI 54821
Contractor: Telephone Number: E -Mail Address:
Rick Yerhot 715-794-2200 (W) / 715-273-8127 ryb@chegnet.net
SECTION B: Properly Information
Project Address (if different from mailing address):
XXXX Birch Point Rd, Cable WI 54821
Legal Description (if additional space is needed attach a separate sheet):
Par in Govt Lot 4 DESC in V. 1102 P.892(356)
Section, Township, Range: 59, T 43N, R6W
Town of: Namakagon
Tax ID /t: 24487
Lot Size (Acres/Square Feet): 54.00 acres
SECTION C: Project Information (check all that apply) ,_,_. ",. , -
Projecl (ice is: El Residential El Commercial El Municipal
Project Type is: O New Construction ❑ Addition/Alteration (existing structure)
❑ Change Use (existing structure) ❑ Relocate (existing structure) El RV Placement 21+ days
❑ Sign 0 Establishing a Business ❑ Temporary (12 or less months)
0 Shoreland Grading, Class A ❑ RV Placement 4+ months, Class A O Other (describe):
required (Total sft): required
SECTION D: Structure Information (Does not apply to RVs and Signs, go to Section E)
Structure Type is: ❑ Residence ❑ Principal Structure (describe):
ID Accessory Structure (describe): 0 Shoreland Exempt Structure (describe): ❑ Mobile Home (provide manufactured
Storage (Cold) date):
❑ Shipping Container ❑ Other (describe):
Foundation Type:
❑ Basement ❑ Walkout Basement El Slab El Crawlspace ❑ Ground ❑ Skids ❑ Other (explain):
Existing Structure: Length: Width: Height:
Proposed Structure (Provide Sq Ft based on outside dimensions, including unfinished areas, attached garages/above grade
decks/porches):
Basement Sq Ft:
l' Floor Sq Ft:
Loft Sq Ft:
2"d Floor Sq Ft:
3`d Floor Sq Ft:
72x30=2,160sgft
Garage Sq Ft:
Porch Sq Ft:
Deck Sq Ft:
Other Sq Ft (describe):
Other Sq Ft (describe):
Total Sq Ft: 2486.4
Overall Height (finished grade to peak): 24
# of Stories: 1
Existing # of Bedrooms on property: 0
Proposed # of Bedrooms in project: 0
S CTION E: RV and Sign Infoimikimi check all that apply)
Sign is:
R V is.
❑ New ❑ Replacement
❑ New ❑ Replacement
El On -premise El Off -premise
El 1 -sided ❑ 2 -sided
Year: Vin #:
❑ On -building El Multi -Tenant
Length: Width: Height:
Make: Model:
Fo) U9r HUU,
P, APP fl a1 /nyt: H,
SECTION F: Site Plan — attach a site plan or draw site plan in box below (See pages 1 & 2 of Land Use Permit Application
Information for information that is required to be provided on site plan) -
Show location of:
❑ Driveways ❑ Frontage Roads (include name) ❑ Existing Structures ❑ Well (W) ❑ Septic Tank (ST) ❑ Drain Field (DF)
❑ Holding Tank (HT) ❑ Privy (P) ❑ Lake ❑ River ❑Stream/Creek ❑Pond ❑Floodplain ❑Wetlands ❑Slopes over 20%
N
See Attachment(s)
Setback or distance from furthest extent of structure
including eaves and overhangs to (include on site plan):
County Use Only
Verified setbacks
Road Centerline
100
ft.
7 Lo ft.
Notes/Comments:
Front Lot Line/Right-of-Way
67 ft.
7S ft.
Side Lot Line I
orth❑East❑South❑WestEl, check one
1 660 ft.
> 7 f ft.
Side Lot Line 2
(NorthDEast0SouthDWestD, check one)
520 ft.
•J
7 7 S' ft.
Rear Lot Line
ft.
7S' ft.
Septic/Holding Tank
ft.
ft.
Drainfield
ft.
ft.
Privy
ft.
ft.
Well
ft.
ft.
Existing Structure/Building
ft.
ft.
Wetland
200 ft.
7 Z ft.
Elevation of Floodplain
ft.
ft.
Ordinary High -Water Mark (OHWM)
300 ft.
-2 7 5 ft.
Other (describe)
ft.
ft.
HCGE�VE0
APR 0 8 2025
SECTIQIY:Additional,.uestions ..-.-
O Yes ❑ No Has the location of the proposed project including eaves and overhangs and the sanita system an we be '
staked? If no, what date will this be completed:
O Yes
❑ No
Did a licensed surveyor mark lot line(s) if project is within 10 feet of required setback? See page 2 of Land Use
Application Information for required setbacks.
❑ Yes
❑ No
Did property owner or applicant mark lot line(s) if project is within 30 feet of required setback? See page 2 of
Land Use Application Information for required setbacks.
❑ Yes
El No
Is there an existing sanitary system on the property? If yes, what kind?
❑ Drainfield ❑ Holding Tank ❑ Municipal/Public ❑ Other (describe):
❑ Yes
El No
Will pressurized water be installed in the structure? If yes, what kind of sanitary system will be installed or used
to manage wastewater?
O Drainfield O Holding Tank O Municipal/Public O Other (describe):
❑ Yes
El No
Will sleeping occur in the structure? If yes, contact local Uniform Dwelling Code (UDC) for approval and
inspection requirements.
Is the project associated with any of the following:
❑ Rezone O Class A Special Use O Class B Special Use O Conditional Use O Variance
Fee payment will be made via:
El Check (attached) O Cash (attached) O debit/credit/echeck (department to call once payment is ready to be taken)
How would you like to receive your permit card?
El Mail to: OR O Email to:
O Property Owner Address El Agent Address O Contractor Address O Other (provide Name and Email or Address):
Section H: Acknowledgement and Sinature �.
All Land Use Permits expire Two (2) Years from the date of issuance if construction or use has not begun. Sanitary Permit
issuance, if required, needs to occur prior to Land Use Permit issuance. Failure to obtain a permit or starting construction without a
permit will result in penalties.
The local Town, Village, City, State or Federal agencies may also require permits. The new construction of one- & two-family
dwellings requires review and approval by the local Uniform Dwelling Code (UDC) authority. Additions and alterations to one -
and two-family dwellings may require review and approval by the UDC authority. All municipalities are required to enforce the
UDC.
If subject property is part of a Condominium Plat, applicant hereby certifies and represents that applicant has all necessary
approvals and recorded documents required to complete the project for which this permit is sought including requirements set forth
in Wisconsin statutes pertaining to condominium associations, the Declaration of the Condominium Association in which the
property is located, and all other rules, regulations and requirements pertaining to that Condominium Association.
You are responsible for complying with state and federal laws concerning construction near or on wetlands, lakes, and streams.
Wetlands that are not associated with open water can be difficult to identify. Failure to comply may result in removal or
modification of construction that violates the law or other penalties or costs. For more information, visit the Department of Natural
Resources wetlands identification web page, dnr.wi._o�pie/wetlands, or contact a Department of Natural Resources service
center (715)685-2900.
I (we) declare that this application, including any accompanying information, has been examined by me (us) and to the best of my
(our) knowledge and belief it is true, correct, and complete. I (we) acknowledge that I (we) am (are) responsible for the detail and
accuracy of all information that I (we) are providing and that will be relied upon by Bayfield County in determining whether to
issue a permit. I (we) further accept liability which may be a result of Bayfield County relying on this information I (we) are
providing in or with this application. I (we) consent to county officials charged with administering county ordinances to have
access to the above -described property at any reasonable time for the purpose of inspection.
Owner(s) or Authorized Agent Printed Name: K.n Ka-mky
Owner(s) or Authorized Agent Signature: 9tl9twoAk/ Date: +ta/zozs
NOTES: Signer ID: XSIVZ5At.
1. If you are signing on behalf of the owner(s) a letter of authorization must accompany this application.
2. Specific conditions/instructions may be stated on the face of the issued Land Use Permits. Owners, agents, & contractors
must all be aware of permit details & conditions and permit card must be posted on property prior to start of project.
BIRCH BEND SITE MAP
PARCELS OWNED IN THE SW —NW, GOVERNMENT LOT 4
AND GOVERNMENT 5. SECTION 9, T. 43 N., R. 6 W., IJN
THE TOWN OF NAMAKAGON, BAYFIELD COUNTY, WISCONSIN
CREATED ON 10/11/24, REVISED ON 10/30/24.
REVISED AGAIN ON 11/08/24
flWO ,
l '4,v
. . . . . . // GOVT LOT 4
y P.xW) /.ice.
. . . . . . . . P
il
- - - -- %1
: .. -... ,,'IIIors. fl
. . . . . . . .GOV'T LOT 5. . . . . . . ..
• ' ' ' ' ' L% 34404 ' I MAMO
axMH:USA . . . . . . . . . . . . . .
24 152 - ............. ].
. .............. (...
........... `'..
. % PMWFR fta3-MA LLC
........./ T451ft18312 RI
. f `
m
u1II APR 08?
Bayfield Co. Zui
=-
ta
I
LAKE NAMEKAGON
. . . . . . . . .`. . uFrvo . . . . . . .�
—' . .
......... <'....
174/ 54//lAY lolA 44450 Lot CF It MOO
MO '450 WO50fl 84/V.
N
. . .
. . . . . . . . . . . . . . ,.
UWHR. U5A
141'5 24753GNHA.
U$ MVI A4RICL[)X 1/5 !PO4/ST4MR'F
SC¢LIWp I2oF T
a o x24144.
V ISO
I® 420
LEGEND
CLIENT. WETHINCTON
NELSON
Qawm vArAa
m Inv)® mL.)m n .vlwia r
i ¢)L4¢ w -Arm
ryw e I #01- ,m )exi ..e kv.�*'num
SURVEYING
Ivw" "I�oc¢\AtW\.a"°°".,"`I°"'iLs c.°'°
INCORPORATED
aIA
/Gip AJM'[WI()fD: IMY/I' \49,iI\H,9_iPoMJ
W Pt
BUSYEY/NO YOUR NECK OF IRE WOODS Ella /854
C
,epi
Dl UUEHIV
,.. U U APR Q "2t��5•.,U
yfieW.Q 9 .f''. >�• r'
o Ba o'Zbn 1 G o
o �� ,i o
Jr
b'0' 77.0
I-6 Sd' T G6' 11'6' T6 11- !6' 1'S E. 9'9'
ODOR MNWW }f I
CONCRETE ___. .___._..I
.... __ _.___ 111FTi i i i T
JIt
Q
79
DR
]E•A81'39.W
I I I
I II
I I PROPOSED NEW STORAGE BUILDING:
-TIMBER POSTS
I I -PREFABWOODTRUSSES I
I
CONCRETE
' CORRUGATED STEEL WALL AND ROOF
APRON
I
CLADDING
- CONCRETE FOUNDATIONS AND SLAB
- ELECTRICAL SUB PANEL FED FROM
I I
__--_______._
I MAINPROPERTY I
------ GRAVEL DRIVE SURROUNDING THREE
------------------
-
LS I
SIDES OF BUILDING
2rS
JJ
STORAGE BUILDING:
-
2,160G �
I I
WIICOA
I
I I I
I
I I
RALLO
TVP POW
o
I o
I%• 1'%O
o
j
APRON
DOOR01
16111'
OVERHEAD
SOUTH ELEVATION
APR 0 2025
Bayfield Co. Zoning D6pt
ICI II II II �I I Ill li�ll
(6) N.116:'N A DOOR 03
54x28 7'87
FIXED
WEST ELEVATION
l4
II I i' III �', II II
Ili Il llllllilllll,l III�IIIII III
DDOR01
1611T j 22'0
NORTH ELEVATION EAST ELEVATION
STORAGE BUILDING - ELEVATIONS scuE: or. or 1a
Birch Bend Residence materiaprima
OTO,...
Bayfield County
Impervious Surface Calculations
�) UHU
1111 APR 0 B 2025
Bayfield Co. Zoning Dept.
These calculations are REQUIRED per WI Admin Code NR 115.05(1)(e) and Section 13-1-32(g) and 13-1-
40(h) of the Bayfield County Code of Ordinances. The undersigned hereby makes application for construction,
reconstruction, expansion, replacement or relocation of any impervious surface within 300 feet of the ordinary
high water mark and agrees that all activities shall be in accordance with the requirements of the Bayfield
County Code of Ordinances and all other applicable ordinances and the laws of the State of Wisconsin.
Pursuant to Chapter 1, Title 13, Section 13-1-106(d) of the Bayfield County Zoning Ordinance(s), Planning and
Zoning Department employees assigned to inspect properties shall have access to said properties to make
inspections.
Property Owner(s):
Michael J & Wendy K Wethington
Mailing Address:
Property Address
1823 Irving Ave S, Minneapolis, MN 55403
XXXX Birch Point Rd, Cable, WI 54821
Legal Description:
Section, Township, Range
1/4, 1/4,
Sec 9 Township 43 N, Range 6 W
Authorized Agent/Contractor
Govt Lot
Lot #
CSM#
Vol & Page
Karl L Kastrosky
�prt of 4
Lot(s) #
Block(s) #
Subdivision
Town of:
Cable
Parcel ID # (PIN #)
Tax ID #
Date:
04-
24487
4/8/2025
Impervious Surface: An area that releases as runoff all or a majority of the precipitation that falls on it.
"Impervious surface" excludes frozen soil but includes rooftops, sidewalks, driveways, parking lots and streets
unless specifically designed, constructed and maintained to be pervious.
Calculation of Impervious Surface: Percentage of impervious surface shall be calculated by dividing the
surface area of existing and proposed impervious surfaces on the portion of a lot or parcel that is within 300
feet of the ordinary high water mark by the total surface area of the lot or parcel, multiplied by 100.
Impervious Surface Standard: Allow up to 15% impervious surface but not more than 30% impervious
surface on the portion of a lot or parcel that is within 300 feet of the ordinary high water mark. A permit can be
issued for development that exceeds 15% impervious surface but not more than 30% impervious surfaces with
a mitigation plan that meets the requirements of the Bayfield County Ordinance(s).
Existing Impervious Surfaces: For existing impervious surfaces that were lawfully placed when constructed
but that do not comply with the standards in Section(s) 13-1-32(g) and Section 13-1-40(h), the property owner
may do any of the following:
a. Maintenance and repair of all impervious surfaces:
b. Replacement of existing impervious surfaces with similar surfaces within the existing building footprint;
c. Relocation or modification of existing impervious surfaces with similar or different impervious surfaces,
provided that the relocation or modification does not result in an increase in the percentage that existed
on the effective date of the county shoreland ordinance, and meets the applicable setback
requirements in Section 13-1-32.
Impervious Surface Item Dimensio{i)11 j (Square Footage)
n III
[Ni APR f) 8
2025
Existing House
Existing Accessory
y le o Lo Zc
iing Dept.
Building/Garage
Existing Sidewalk(s), Patio(s) &
Deck(s)
Existing Covered Porch(es),
Driveway & Other Structures
Proposed Addition/House
Proposed Accessory
72 x 30 + Overhangs =
2486
Building/Garage
Proposed Sidewalk(s) & Patio(s)
Proposed Covered Porch(es) &
Deck(s)
Proposed Driveway
35x46
1610
10 x 60
600
Proposed Other Structures
Total:
7318
a. Total square footage of lot:
b. Total impervious surface area:
c. Percentage of impervious surface area: 100 x (b)/a = 0.31
If the proposed impervious surface area is greater than 15% mitigation is required.
Total square footage of additional impervious surface allowed: @ 15% @ 30%
Issuance Information (County Use Only)
Date of Inspection:
Inspection Record:
Zoning District I
Lakes Classification (
Condition(s):
Stormwater
Management Plan Required:
❑ Yes ❑ No
Signature of Inspector:
Date of Approval:
u/fomisrimpervioussurface
Created: May 2012 (®Apr 2016; Sept 2020) Proofed by:
Ksstr0sky821 LLC
�r
,dot
Kari Kasrrosky
Land IrM Mepr&r,/ ( '
715-580-0157 D ICl HiUU D
14295MfVou&1PRd SkW 41 APR 082025
stTOSky8?1 n m ti. n fi eld Co. Zoning Dept.
ToW!14uv A May-cun r®r.
i Re try uttmnxr $Mf it trn is en at rme .agent'u prpcuna prnn(th n•:I
ac ss frrhnm�at►ar� Pe'f n9ILI ffw ctopoty Et _ - ` t�
IniheTaA t)4 QusnuYof �. - .�
M cuSad k*wt yfynn It
ht
Email'+_.'
Land Use Permit Application Re�iew Checklist
Submission #: "D
What zoning district is the project located in?
❑ R-1 -2 ❑ R-3 ❑ R-4 ❑ R-RB ❑ C Dl ❑ M ❑ A-1 ❑ A-2 ❑ F-1 ❑ F-2 ❑ W ❑ M -M
❑ Yes 'No
Is lot substandard (does not meet current zoning dimensional requirements)?
/
Deed of record:
Yes ❑ No
Is the project located in the Shorelands (Shorelands are lands within 300 feet of a river/stream OR
landward side of floodplain OR 1000 feet of a lake/pond/flowage, whichever is greater)?
Yes ❑ No
Is impervious surface required? (Required if riparian lot OR lot is entirely within 300 feet of OHWM of
navigable waterway)
❑ Yes lclo
Is the project located in the Floodplain?
1
Zone:
Yes ❑ No
Are there wetlands on the property?
b Yes No
Is project associated with a nonconforming use or structure?
❑ Yes No
Is project associated with a variance?
Case #:
❑ Yes No
Is project associated with a Special B or Conditional Use Permit?
/
Permit #:
❑ Yes o
Is the project associated with a Special A Use Permit? _
Does the project require sanitary?
❑ Yes PNo
0 Existing 0 New 0 Intercept ❑ Reconnect ❑ Non -Plumbing ❑ Public
Sanitary Permit #:
❑ Yes -'No
Does the project require mitigation?
Implementation Deadline: Date of Compliance:
❑ Yes -No
Does the project require an affidavit?
Affidavit #:
❑ Yes No
Did licensed surveyor mark lot line(s), if project is within 10 feet of required setback?
❑ Yes Jo
Did applicant/property owner mark lot line(s), if project is within 30 feet of required setback?
Project use is?7ResidentiaI ❑ Commercial ❑ Municipal
Project type is? New Construction ❑ Addition/Alteration ❑ Change Use ❑ Relocate ❑ RV Placement ❑ Sign
❑ Establishing a Business ❑ Temporary ❑ Shoreland Grading ❑ Other, describe:
Structure Type is: ❑ Residence O Principal Structure 0%ccessory Structure ❑ Boathouse (one story only)
❑ Open-sided/Screened Structure (gazebo, etc.) ❑ Stairway to navigable waters ❑ Mobile Home
❑ Shipping Container ❑ Other, describe
Total Sq. Ft. of Project: 'L4 g� Number of Stories: Overall Height:
Calculated Fee Category:
❑ Residential Principal Structures - $0.75/square foot (minimum $125)
❑ Habitable Residential Accessory Structures - $0.50/square foot (minimum $75)
❑ Non -Habitable Residential Principal and Accessory Structures - $0.20/square foot (minimum $75)
❑ Commercial/Municipal Principal Structures - $0.75/square foot (minimum $125)
❑ Commercial/Municipal Acce sory Structures - $0.20/square foot (minimum $75)
Calculated Fee Amount: 'L9"
Additional Fees: O Return Inspection ❑ Land Use Revisions ❑ Special Use Permit - Class A ❑ After -the -Fact (ATF)
❑ Floodplain ❑ Shoreland - Impervious Surface ❑ Shoreland - Non -Conforming, etc. ❑ Tower Siting/Collocation 1
❑ Tower Collocation 2 ❑ Metallic Mine
ATF Fee Amount:
Inspected by: ,n
„
Date of Inspection:
u
Re -Inspected by:
Date of Re -Inspection:
Denied by:
Date of Denial:
Reason for Denial:
Date Denial Letter Mailed:
Approved by: AV Date of Approval:
Cond' ' (s):
ust eet and maintain setbacks from furthest extension of structure including eaves and
ove ngs.
For personal storage only.
❑ Fprrsonal residence only.
l4Jot for human habitation or sleeping purposes.
❑ Town/State/DNR/Federal may require permitting
❑ A Uniform Dwelling Code (UDC) Permit from the locally contracted UDC Inspection Agency must be
obtained prior to the start of construction.
❑ A Uniform Dwelling Code (UDC) Permitfrom the locally contracted UDC Inspection Agency must be
obtaid prior to the start of construction (if applicable).
se best management practices to limit and prevent erosion during construction.
❑ This permit cannot be transferred if property is sold.
❑ A Bayfield County Health Dept permit is required.
❑ Check with Town regarding room tax.
❑ Short -Term Rental is for a maximum occupancy of persons.
❑ Si..must meet the requirements of Article E of the Bayfield County Zoning Ordinance.
i&10 be constructed per plan.
❑ Adhere to privy agreement.
❑ Temporary permit allowing existing structure for a period of less than 1 year.
❑ RV may not be used for permanent residence or storage.
❑ RV allowed for
❑ RyaiThst be removed by
No�seWG r and pressurized water allowed in the structure.
t1Iopkmbing or plumbing fixtures allowed.
'.`�c dditional sleeping areas allowed without obtaining necessary sanitary permit(s).
4kdnd use permits shall be required for any new residence, any building or structure erected,
reloc ed, rebuilt, or structurally altered
-rfEand use permits shall be obtained prior to the initiation of construction or a change in land use
❑ Requirements (e.g., permits/licensing/tax) of Local Town, Village, City, State or Federal agencies are
required
❑ Sanitation requirements must be met (if applicable)
❑ Additional conditions may be placed and need to be adhered to at the time of permit issuance
Other Conditions:
B-YFIELD Bayfield County
Planning & Zoning Department
117 E 5th Street
P.O. Box 58
Washburn, WI 54891
Phone: 715-373-6138
Fax: 715-373-0114
Property Owner: Submission Number:
WETHINGTON, MICHAEL J & WENDY K LU-01580
1823 IRVING AVE S
MINNEAPOLIS, MN 55403 Transaction Number:
LU-01580-27722
Description Amount
Shoreland - Impervious Surface $25.00
Verified Fee Amount $0.00
Non -Habitable Residential Principal and Accessory $497.28
Structures - $0.20/square foot (minimum $75)
Total: $522.28
Payment Amount: $523.53
Reference: 5561599355
Paid by: Mike & Wendy Wethington
Payment Type: Electronic Funds Transfer
Transaction Date: undefined
Receipt of payment does not guarantee eligibility of
permit and is not proof of issuance of a permit.
Town, City, Village, State or Federal
Permits May Also Be Required
Substandard - No / Nonconforming - No
Shoreland — Yes I Impervious Surface - Yes
Floodplain - No / Wetlands - Yes
Mitigation - No / Affidavit #:
LAND USE - X
SANITARY -
SPECIAL A -
SPECIAL B/CONDITIONAL —
BOA —
No. 25-0246 Tax ID: 24487
Issued To: WETHINGTON, MICHAEL J & WENDY K
Location: S09 - T43N - R06W
Town of Namakagon
BAYFIELD COUNTY
Legal Description: PAR IN GOVT LOT 4 DESC IN V.1102 P.892 356
PERMIT
WEATHERIZE AND POST THIS PERMIT
ON THE PREMISES DURING CONSTRUCTION
Residential Structure in R-2 zoning district
For: New Construction [I - Story], Accessory Structure on a Slab [2486.4 Total sq. ft.] Height of 24'
(Disclaimer): You are responsible for complying with state and federal laws concerning construction near or on wetlands, lakes, and streams. Any
future expansions or development would require additional permitting.
Condition(s): See back of card
NOTE: This permit expires two years from date of issuance if the authorized construction
work or land use has not begun.
Changes in plans or specifications shall not be made without obtaining approval.
This permit may be void or revoked if any of the application information is found
to have been misrepresented, erroneous, or incomplete.
This permit may be void or revoked if any performance conditions are not
completed or if any prohibitory conditions are violated.
Scott Roush
Authorized Issuing Official
May 07, 2025
Date
Condition(s): Must meet and maintain setbacks from furthest extension of structure including eaves and overhangs.
For personal storage only.
Not for human habitation or sleeping purposes.
Use best management practices to limit and prevent erosion during construction.
To be constructed per plan.
No sewer and pressurized water allowed in the structure.
No plumbing or plumbing fixtures allowed.
No additional sleeping areas allowed without obtaining necessary sanitary permit(s).
Land use permits shall be required for any new residence, any building or structure erected, relocated, rebuilt,
or structurally altered
Land use permits shall be obtained prior to the initiation of construction or a change in land use